Send Message
Home ProductsAir Cooled Water Chiller

Low Temperature R22 Air Cooled Water Chiller 71kW COP 3.68 380V 50Hz

Certification
China Pultruded FRP Online Market certification
China Pultruded FRP Online Market certification
Customer Reviews
I recently placed an order and I needed to update that order prior to shipment. The staff was responsive and courteous.

—— Mr.smith

You always can give me the best plan ,and it lets my customer feel great,i hope we can have another chance to cooperation.

—— Tim

Very appreciate for your professional service & higher standard quality control,very happy to know you.

—— Mr Johnifere

I'm Online Chat Now

Low Temperature R22 Air Cooled Water Chiller 71kW COP 3.68 380V 50Hz

Low Temperature R22 Air Cooled Water Chiller 71kW COP 3.68 380V 50Hz
Low Temperature R22 Air Cooled Water Chiller 71kW COP 3.68 380V 50Hz

Large Image :  Low Temperature R22 Air Cooled Water Chiller 71kW COP 3.68 380V 50Hz

Product Details:
Place of Origin: China
Brand Name: EuroKlimat
Certification: AHRI ,CE,ISO9001,ISO14001,OHSAS18001
Model Number: EKAC 250BRLH
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: negotiation
Packaging Details: Carton
Delivery Time: 20 working days after received your payment
Payment Terms: L/C, T/T
Supply Ability: 50 pcs per month

Low Temperature R22 Air Cooled Water Chiller 71kW COP 3.68 380V 50Hz

Description
Product Name: Low-temp High-efficiency Model Air-cooled Heat Hump Unit Limiting Temperature: -20 ℃ Cooling And 48℃ Heating
Heating Capacity Range: 75-1200 Cooling Capacity Range: 71 KW-1136 KW
COP: 3.68 IPLV: 4.33
High Light:

air source heat pump

,

heat pump outside unit

 

71kW COP 3.68 Low-temp high-efficiency model air cooled modular chiller / heat pump unit

 

 

Specifications:

 

Technical data sheet

 

 

Model   EKAC 250BRLH EKAC 500BRLH EKAC 750BRLH EKAC 1000BRLH EKAC 1250BRLH EKAC 1500BRLH
Unit combination Master unit EKAC 250BRLHM EKAC 250BRLHM EKAC  250BRLHM EKAC 250BRLHM EKAC 250BRLHM EKAC 250BRLHM
slave unit -- EKAC 250BRLHS 2EKAC 250BRLHS 3EKAC 250BRLHS 4EKAC 250BRLHS 5EKAC 250BRLHS
Nominal cooling capacity kW 71 142 213 284 355 426
USRT 20.19 40.38 60.57 80.76 100.95 121.14
×104kcal/h 6.10 12.2 18.3 24.4 30.5 36.6
Nominal heating capacity kW 75 150 225 300 375 450
USRT 21.33 42.66 63.99 85.32 106.65 127.98
×104kcal/h 6.45 12.9 19.35 25.8 32.25 38.7
Total power of nominal cooling capacity kW 19.3 38.6 57.9 77.2 96.5 115.8
Total power of nominal heating capacity kW 20.0 40 60 80 100 120
Power supply   380V/3N~/50Hz
Refrigerant Type   R22
Control   Electronic expansion valve
Compressor Type   Fully hermetic volute compressor
Lubricant   Mineral oil (SUNISO 3GS)
Qty. Set 2 4 6 8 10 12
Fan Type   High-efficiency vacuum braze-welded panel type
Qty. Set 2 4 6 8 10 12
Water side heat exchanger Type   High-efficiency vacuum braze-welded panel type
Water flow for
cooling
3
m /h
12.2 24.4 36.6 48.8 61 73.2
Water flow rate in
heating mode
3
m /h
12.9 25.8 38.7 51.6 64.5 77.4
Water resistance kPa 36 36 36 36 36 36
Recommended diameter for general inlet/outlet water pipe inch ≥2 ≥3 ≥3 ≥4 ≥4 ≥5
Power cable specification Section area of live line 2
mm
≥10 ≥35 ≥70 ≥95 ≥120 ≥150
Qty. of live lines   3
Section area of null line 2
mm
≥4
Qty. of null lines   1
Section area of grounding line 2
mm
≥10 ≥16 ≥35 ≥50 ≥60 ≥75
Qty. of grounding lines   1
Dimensions L x H mm 2012×1840
Width mm 880 2125 3370 4615 5860 7105
Unit weight Net weight kg 590 1180 1770 2360 2950 3540
Operating weight kg 600 1200 1800 2400 3000 3600

 

Note:
■ Test conditions for nominal cooling capacity: outlet water temperature 7°C; water flow: 0.172m3/(h·kw); outdoor ambient temperature 35°C.
■ Test conditions for nominal heating capacity: outlet water temperature 45°C; water flow: 0.172m3/(h·kW); outdoor dry/web bulb temperature
7°C/6°C.
■ Water resistance at the air conditioner side includes water pressure drop of the unit and the attached Y-shaped filter.
■ Main Pipes of combined units need to be customized and installed on site. The diameter of the pipes must meet design requirements. EK
does not provide the pipes.
■ Modular units can be formed using the 1 - 16 basic modules of same type or of different types as per practical needs. The above table lists
the parameters for common module combinations.
■ For on-site electric wiring, see the name plate or installation menu of the unit.

 

Decription

 

1. The low-temperature high-efficiency modular air cooled heat pump unit features a full-load COP up to 3.68, meeting the national standard for tier-1 energy saving products (3.4). Both the cooling and heating energy efficiency of the low-temperature high efficiency modular air-cooled heat pump unit is greatly improved to save operation cost for customers (value added). The energy efficiency is especially excellent with partial workload, bringing comfort to customers at much lower cost.

2. The EKAC low-temperature high-efficiency unit features leading-edge EVI (Enhanced Vapor Injection) compressors, increasing refrigerant recycling by as much as 20%. The evaporation capacity is improved by mid-pressure refrigerant intake. One compressor compresses refrigerant 2 times in each cycle. Half-M fins are used to improve the heat-exchange efficiency of the heat exchanger. The unit features state-of-the-art cross diagonal convection angles for stainless steel braze-welded panel-type heat exchanger and stainless steel braze welded panel-type economizer (used to increase the enthalpy differentiation between the inlet and outlet of the evaporator). An EXV is used to precisely control the operation of the unit.

3. The EKAC low-temperature high-efficiency modular air-cooled heat pump unit features excellent heating COP when the ambient temperature is low (20% higher than common air-cooled heat pump unit when the ambient temperature is -10°C). The lower ambient temperature limit is expanded from -10°C of common units to -20°C. This greatly improves cooling performance in areas where the winter is cold, reducing or eliminating the need for auxiliary heaters

4. Each modular unit has two power gears. When multiple modular units are combined, there could be many power gears. When working at a partial workload (99% of the operation time), the unit intelligently regulates the output based on the actual workload, making the operation efficiency even higher. With an optional 2-way valve water control feature, the unit can send out signals to cut off chilled water. This enables automatic flow control for pumps in line with the transducer, which helps save more energy.

5.  Currently, centralize heating by using heat pipes are very common. This type of heat provision wastes a lot of heat in the heating pipes, and is low in efficiency. Other defects include fixed heating period, environment pollution, difficult to maintain and collection fees, and not meeting national requirements on energy saving. The EKAC low-temperature high-efficiency modular air-cooled heat pump unit can provide enough heat in an ambient temperature as low as -20°C. The heating period, output capacity, and indoor temperature can be flexibly conditioned as required by the customer. The unit provides both heating and cooling functions, saving installation and maintenance costs. Unit of this series meets the trend for energy saving technologies, and is revolutionary compared with traditional heat provision solutions.