Send Message
Home ProductsAir Cooled Water Chiller

Eco friendly R407C Refrigerant HVAC Chiller , Phase reversion protection

Certification
China Pultruded FRP Online Market certification
China Pultruded FRP Online Market certification
Customer Reviews
I recently placed an order and I needed to update that order prior to shipment. The staff was responsive and courteous.

—— Mr.smith

You always can give me the best plan ,and it lets my customer feel great,i hope we can have another chance to cooperation.

—— Tim

Very appreciate for your professional service & higher standard quality control,very happy to know you.

—— Mr Johnifere

I'm Online Chat Now

Eco friendly R407C Refrigerant HVAC Chiller , Phase reversion protection

Eco friendly R407C Refrigerant HVAC Chiller , Phase reversion protection
Eco friendly R407C Refrigerant HVAC Chiller , Phase reversion protection Eco friendly R407C Refrigerant HVAC Chiller , Phase reversion protection

Large Image :  Eco friendly R407C Refrigerant HVAC Chiller , Phase reversion protection

Product Details:
Place of Origin: Guangdong
Brand Name: GOLDEN
Certification: CE
Model Number: HLWH-100SHM~320SHM
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Price: Negotiable
Packaging Details: Wooden Case
Delivery Time: 10 working days after received your payment
Payment Terms: T/T, Western Union, L/C, MoneyGram
Supply Ability: 500pcs per month

Eco friendly R407C Refrigerant HVAC Chiller , Phase reversion protection

Description
Cooling Capacity(KW): 101-316 Chilled Water Flow(m³/h): 17.4-54.3
Power Supply: 380v-50hz-3ph Refrigeration: R407C
Heating Capacity(KW): 111-337 Condenser: Ripple Aluminum Fins Around Copper Pipe
Certificate: CE Mount Type: Free Standing
High Light:

Modular Air Cooled Chiller

,

Air Cooled Chilled Water System

 

Eco friendly R407C Refrigerant HVAC Chiller , Phase reversion protection

 

 

Description

 

Environment-friendly refrigerant air cooled water chiller with heat recovery for daily life , air source heat pump for HVAC

 system.

 

Model     HLWH~

100SM

150SM

195SM

230SM

270SM

290SM

320SM


Rated Cooling Capacity

Cooling 

Capacity (KW)

101

147

196

232

268

293

316

Comp. 

Input Power (KW)

34.6

48.2

63.8

70.5

82.4

90.2

98.9


Rated Heating Capacity

 Heating 

Capacity (KW)

111

159

212

245

284

311

337

Comp. 

Input Power (KW)

34.1 

47.4 

62.8 

69.2 

80.8 

88.4 

97.2 

 Refrigerant 

R407C

Power Supply 

3φ-380V/50HZ

Safety Protection

Phase reversion protection, 

Phase lack protection, 

Overload current protection,
Discharge air temp.  protection, 

Low & High pressure protection, 

Low temp.  protection, 

Water flow protection.

 Number of Refrigeration Circuit

1

Capacity Control (%)

0, 50, 75, 100

 Refrigerant Charge (Kg)

30

42

56

68

78

84

93

Air Cooled Heat Exchanger

Ripple Aluminum Fins Around Copper Pipe


Water Cooled Heat Exchanger

Dia.of Pipe (inch)

2-1/2"

3"

3"

3"

4"

4"

4"

Water Side 

Max Pressure  (MPa)

1

 Chilled  

Water Flow(m3/h)

17.4

25.3

33.7

39.9

46.1

50.4

54.3

 Water 

Pressure Drop (kPa) 

28

33

48

55

61

64

66

Flow of Hot 

Water(m3/h)

19.1

27.3

36.5

42.1

48.8

53.5

58.0


Axial Fan

Air Flow×1000m3/h

56.8

80.4

113.6

115.2

115.2

160.8

160.8

Power×Qty (KW)

1.2×4

2.0×4

1.2×8

1.2×8

1.2×8

2.0×8

2.0×8

Running Noise dB(A)

75

75

75

75

75

75

75

Total Weight (Kg)

1550

1960

2940

3120

3300

3480

3660

Running Weight(Kg)

1660

2140

3160

3340

3550

3730

3980

 

 

Heat Recovery

 

Refrigerant Charge (Kg)

35

47

54

76

85

92

101

Heat Reclaimed Volume  (KW)

30

44

59

70

80

88

95

Heat Recovery

Dia.of Pipe (inch)

1-1/2"

1-1/2"

1-1/2"

2"

2"

2"

2"

Water Side Max Pressure  (MPa)


Reclaimed  Water Flow (m3/h)

5.2

7.6

10.1

12.0

13.8

15.1

16.3

Water Pressure drop (kPa) 

24

23

27

27

26

26

26

Total Weight (Kg)

1720

2160

3180

3360

3550

3770

3980

Running Weight(Kg)

1870

2400

3450

3680

3910

4200

4390

 

 

Note :

 

1.  Rated Cooling Capacity Based on : DB Temperature 35 ℃ / WB Temperature 24 ℃

   Chilled water inlet/outlet temp. 12 ℃ /  7℃ ,  Fouling factor: 0.088㎡.°C/KW.

2.  Rated Cooling Capacity Based on : DB Temperature 7℃/WB Temperature 6 ℃

    Hot water inlet/outlet temp. 40 ℃ / 45 ℃ ;  Hot water range: 45 ℃~45 ℃;

2.  Chilled Water Range: 5~20℃ ;  Lowest Ambient Temperature: -5 ℃~43 ℃;

3.  Heat recovery unit water in/out temperature: 50 ℃ / 55 ℃;

4. Changes of Specification for lmprovement May Be made without Notice.

 

 

Feature:

 

1. Cooling capacity: 101KW - 316KW ,  Heating capacity : 111KW - 337KW

 

2 . Compact design, reliable operation;

 

3 . Micro-computer control intelligently, English display, and friendly interface. Operating information is clear at a glance.

 

4 . Micro-computer and electrical control elements are brand products and imported from world. The products has 

good quality, and reliable features

 

5 . The unit may install on roof of the building, ground or other location, where does not need equipment room.

 

6 . The installation of air cooling chiller is simply in comparison with that of water cooling chiller, no need

 to work with cooling tower or cooling water pipeline. The unit is compact in structure and covers small land 

area .You only need to connect the water pipeline between load and evaporator and supply during installation

 

Unit within heat recovery , can provide hot water for daily life . 

 

 

Product Show 

 

Eco friendly R407C Refrigerant HVAC Chiller , Phase reversion protection 0

Contact Details
Pultruded FRP Online Market

Contact Person: cschen

Tel: +86 1987546789

Fax: 86-10-23898923-33

Send your inquiry directly to us (0 / 3000)