Send Message
Home ProductsAir Cooled Water Chiller

Flexible Type Air Cooled Water Chiller Heat Pump Environment protection

Certification
China Pultruded FRP Online Market certification
China Pultruded FRP Online Market certification
Customer Reviews
I recently placed an order and I needed to update that order prior to shipment. The staff was responsive and courteous.

—— Mr.smith

You always can give me the best plan ,and it lets my customer feel great,i hope we can have another chance to cooperation.

—— Tim

Very appreciate for your professional service & higher standard quality control,very happy to know you.

—— Mr Johnifere

I'm Online Chat Now

Flexible Type Air Cooled Water Chiller Heat Pump Environment protection

Flexible Type Air Cooled Water Chiller Heat Pump Environment protection
Flexible Type Air Cooled Water Chiller Heat Pump Environment protection

Large Image :  Flexible Type Air Cooled Water Chiller Heat Pump Environment protection

Product Details:
Place of Origin: Guangdong
Brand Name: GOLDEN
Certification: CE
Model Number: HLWH-360DM-630DM
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Price: Negotiable
Packaging Details: Wooden Case
Delivery Time: 10 working days after received your payment
Payment Terms: T/T, Western Union, L/C, MoneyGram
Supply Ability: 500pcs per month

Flexible Type Air Cooled Water Chiller Heat Pump Environment protection

Description
Cooling Capacity(KW): 358-632 Power Supply: 380v-50hz-3ph
Heating Capacity(KW): 387-675 Condenser: Ripple Aluminum Fins Around Copper Pipe
Certificate: CE Mount Type: Free Standing
Chilled Water Flow(m³/h): 61.6-108.7
High Light:

Air Cooling Units

,

Modular Air Cooled Chiller

 

Flexible Type Air Cooled Water Chiller Heat Pump Environment protection

 

 

     Model     HLWH~

360DM

390DM

460DM

490DM

540DM

590DM

630DM

Rated Cooling 

Capacity

 Cooling 

Capacity (KW)

358

391

464

490

536

586

632

 Comp. 

Input Power (KW)

116.4

127.6

141.0

148.2

164.8

180.4

197.8

Rated Heating

 Capacity

 Heating

 Capacity (KW)

387

423

491

518

569

622

675

 Comp.

 Input Power (KW)

114.4 

125.6

138.3 

145.4 

161.7 

176.9 

194.4

 Refrigerant 

R407C

 Power Supply 

380V/ 3ph/ 50Hz

 Safety Protection

Phase reversion protection, 

Phase lack protection, 

Overload current protection,
Discharge air temp.  protection,

 Low & High pressure protection,

 Low temp.  protection, 

Water flow protection.

 Number of 

Refrigeration Circuit

2

 Capacity Control (%)

0, 25, 37.5, 50, 62.5, 75, 87.5, 100

  Refrigerant Charge (Kg)

114

122

146

150

164

178

196

 Air Cooled

 Heat Exchanger

Ripple Aluminum Fins Around Copper Pipe

Water Cooled Heat Exchanger

 Dia.of Pipe (inch)

5"

5"

3"×2

3"×2

4"×2

4"×2

4"×2

Water Side 

Max Pressure  (MPa)

1

 Chilled  

Water Flow(m3/h)

61.6

67.2

79.8

84.3

92.2

100.8

108.7

 Water 

Pressure 

Drop (kPa) 

42

54

44

52

54

55

65

 Flow of 

Hot Water(m3/h)

66.6

72.7

84.4

89.1

97.9

107.0

116.1

Axial Fan

Air Flow×1000m3/h

172.8

172.8

230.4

230.4

230.4

321.6

321.6

 Power×Qty (KW)

1.2×12

1.2×12

1.2×16

1.2×16

1.2×16

2.0×16

2.0×16

 Running Noise dB(A)

75

75

75

75

75

75

75

 Total Weight (Kg)

5620

5800

6240

6430

6600

6960

7320

Running Weight(Kg)

6040

6280

6680

6850

7100

7460

7960

 

1. Rated Cooling Capacity Based on: DB Temperature 35℃/WB Temperature 24℃

   Chilled water inlet/outlet temp. 12℃/7℃,  Fouling factor: 0.088㎡.°C/KW.

2. Rated Cooling Capacity Based on: DB Temperature 7℃/WB Temperature 6℃

    Hot water inlet/outlet temp. 40℃/45℃;  Hot water range: 45℃~45℃;

2. Chilled Water Range: 5~20℃;  Lowest Ambient Temperature: -5℃~43℃;

3. Heat recovery unit water in/out temperature: 50℃/55℃;

4.Changes of Specification for lmprovement May Be made without Notice.

 

 

Feature : 

  

Flexible configuration

The unit and tank flexible configuration.A different water tank to choose,pressure or open type connected to

 meet the different demands of clients.

 

Environment Friendly

Using refrigerant 407C or 410A, no damage,environment friendly.

 

Simple operation

Intelligent design, LCD display, simple operation, free setting during 30 ° c - 60° c and cycle timing set 

on/off freely.

 

Quiet running

Using efficient, low-noise rotary, closed scroll compressors and low-noise fan,ensure quiet running.

 

Working environment

Applicable to -15°C~45°C- the outdoor harsh environment temperature, all-weather work.

 

Wide application

Widely used for room radiant, floor heating, schools, factories, apartments, sauna, SPA association, beauty

 salon, fitness center, guesthouse, hotel, hospital, senior residential, swimming pool, factories, farms, 

greenhouse production process etc, can replace the fuel gas boiler and heating boilers, water equipment etc.

 

Modular design

Multi-modular units adopt module combined structure to increase unit’s flexibility in transportation, installation, 

adjustment and maintain and reduce fee for transportation, installation and equipment maintain.

 

 

Unit protection components

The units have thermal protection switch, overload relay, high/low pressure switch, paddle flow switch and 

delay-starting protection devices to ensure unit runs under safety, reliable working condition and unit is easy to

 maintain and repairing.

 

Contact Details
Pultruded FRP Online Market

Contact Person: cschen

Tel: +86 1987546789

Fax: 86-10-23898923-33

Send your inquiry directly to us (0 / 3000)