Send Message
Home ProductsAir Cooled Water Chiller

Domestic Air Cooled Versus Water Cooled Chillers 380V / 3ph / 50Hz

Certification
China Pultruded FRP Online Market certification
China Pultruded FRP Online Market certification
Customer Reviews
I recently placed an order and I needed to update that order prior to shipment. The staff was responsive and courteous.

—— Mr.smith

You always can give me the best plan ,and it lets my customer feel great,i hope we can have another chance to cooperation.

—— Tim

Very appreciate for your professional service & higher standard quality control,very happy to know you.

—— Mr Johnifere

I'm Online Chat Now

Domestic Air Cooled Versus Water Cooled Chillers 380V / 3ph / 50Hz

Domestic Air Cooled Versus Water Cooled Chillers 380V / 3ph / 50Hz
Domestic Air Cooled Versus Water Cooled Chillers 380V / 3ph / 50Hz Domestic Air Cooled Versus Water Cooled Chillers 380V / 3ph / 50Hz Domestic Air Cooled Versus Water Cooled Chillers 380V / 3ph / 50Hz

Large Image :  Domestic Air Cooled Versus Water Cooled Chillers 380V / 3ph / 50Hz

Product Details:
Place of Origin: Guangdong
Brand Name: GOLDEN
Certification: CE
Model Number: HLWA-110SH~340SH
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Price: Negotiable
Packaging Details: Wooden Case
Delivery Time: 10 working days after received your payment
Payment Terms: T/T, Western Union, L/C, MoneyGram
Supply Ability: 500pcs per month

Domestic Air Cooled Versus Water Cooled Chillers 380V / 3ph / 50Hz

Description
Cooling Capacity(KW): 109-337 Input Power(KW): 34.7-99.9
Power Supply: 380v-50hz-3ph Refrigeration: R22/R407C
Chilled Water Flow(m³/h): 18.7-58 Condenser: Ripple Aluminum Fins Around Copper Pipe
Certificate: CE Mount Type: Free Standing
High Light:

Air Cooling Units

,

Air Cooled Chilled Water System

 

Domestic Air Cooled Versus Water Cooled Chillers 380V / 3ph / 50Hz

 

Model HLWA~

110SH

160SH

210SH

240SH

280SH

310SH

340SH


Rated Cooling 

Capacity

X 1000Kcal/h

93.6

133.6

178.7

210.6

243.4

263.5

290.1

KW

109

155

208

245

283

307

337

 Comp. lnput 

Power×Qty (KW)

34.7×1

47.7×1

63.2×1

71.2×1

82.4×1

89.9×1

99.9×1

Refrigerant 

R22

 Power Supply 

380V / 3ph / 50Hz

 Safety Protection

Phase reversion protection, 

Phase lack protection, Overload 

current protection,
Discharge air temp.  protection,

 Low & High pressure protection, Low temp. 

 protection, Water flow protection.

 Number of Refrigeration Circuit

1

 Capacity Control (%)

0, 50, 75, 100

  Refrigerant Charge (Kg)

30

42

56

68

78

84

93

   Condenser

Ripple Aluminum Fins Around Copper Pipe


Evaporator

Dia.of Pipe (inch)

2-1/2"

3"

3"

3"

4"

4"

4"

Water Side Max 

Pressure  (MPa)

1

Chilled  Water Flow(m3/h)

18.7

26.7

35.7

42.1

48.7

52.7

58.0

 Water Pressure drop (kPa) 

28

33

48

55

61

64

66

Axial Fan

Air Flow×1000m3/h

56.8

80.4

113.6

115.2

115.2

160.8

160.8

Power×Qty (KW)

1.2×4

2.0×4

1.2×8

1.2×8

1.2×8

2.0×8

2.0×8

Running Noise dB(A)

68

68

68

68

72

72

72

Total Weight (Kg)

1160

1730

2590

2670

2750

2930

3160

Running Weight(Kg)

1270

1920

2810

2900

3020

3240

3450

Heat Recovery

 

Refrigerant Charge (Kg)

32

44

59

71

80

87

96


Heat Reclaimed Volume (kw)

X 1000Kcal/h

28.1

40.1

53.6

63.2

73.0

79.1

87.0

KW

33

47

62

73

85

92

101

Heat Recovery

 Dia.of Pipe (inch)

1-1/2"

1-1/2"

1-1/2"

2"

2"

2"

2"

Water Side Max Pressure  (MPa)

Reclaimed  Water Flow (m3/h)

5.6

8.0

10.7

12.6

14.6

15.8

17.4

Water Pressure drop (kPa) 

24

23

27

27

26

26

26

 Total Weight (Kg)

1350

1930

2840

2960

3130

3240

3490

 Running Weight(Kg)

1480

2170

3100

3250

3380

3620

3860

 

 

Note: 

 

  1. Rated Cooling Capacity Based on: DB Temperature 35℃/WB Temperature 24℃ 

 Chilled water inlet/outlet temp. 12℃/7℃,  Fouling factor: 0.088㎡.°C/KW.

2. Chilled Water Range: 5~20℃;  Lowest Ambient Temperature:15℃~43℃;

3. Heat recovery unit water in/out temperature: 50℃/55℃;

4.Changes of Specification for lmprovement May Be made without Notice.

 

 

Features:

 

1. Wide capacity range:

1) The various type units with range of cooling capacity from 109KW – 337KW;

2) Each one has cooling only and cooling (heating) type;

3) There are integrity and modular structure;

4) Each one has regular computer control type and luxury computer control type;

5) Provide optional components of auxiliary electrical 

heater, build-in water pump, and paddle flow switch etc. according to customer requirements.

6) The unit may use no-standard refrigerant. It may be low water temperature type glycol for air cooled water

 chiller unit, or double refrigerants unit, air cooled compress condensing unit, etc. Please contact us for detail.

The unit has high efficient, less energy consume, and low operating fee features.

 

2. Huali Company use brand high EER semi-hermetic type compressor, condenser, and cooling accessories 

from world and adopt advance technology in air conditioning and control. High quality process equipments

 and testing-center to ensure the units have energy saving and reliable features.

 

3. Unit protection components

 

The units have thermal protection switch, overload relay, high/low pressure switch, paddle flow switch and 

delay-starting protection devices to ensure unit runs under safety, reliable working condition and unit is easy to 

maintain and repairing.

 

  1. Super low noise, operating quietly

1) Semi-hermetic compressor has operating steady, low noise, and less vibration features.

 2) Brand condensing. The unit structure is simply with good air dynamic features and to ensure fan works

 under low noise and high efficiency.

 

 

Product show: 

Domestic Air Cooled Versus Water Cooled Chillers 380V / 3ph / 50Hz 0

Contact Details
Pultruded FRP Online Market

Contact Person: cschen

Tel: +86 1987546789

Fax: 86-10-23898923-33

Send your inquiry directly to us (0 / 3000)